πŸ“„ V1.08.0

TA Select V1.08.0


πŸ’‘
Effective date: September 02, 2026

A new version of TA Select has been released, and it is now available to download from the following link.

Download instructions:

Step 1: Delete existing TASelect folder before installing new update. Delete existing folder C:\TASelect

Step 2: Navigate to TA Select online portal ➑️ [Downloads] section in navigation menu ➑️ download and install [TASELECT_SALES_V1.08.0]

Step 3: Download and install the hotfix 

Step 4: Once you open the section, enter your CCSI username and password. (As shown in the image below)

Release notes:

πŸŽ›οΈFan Selection

  • Nicotra Gebhardt fan integration: COPRA EC fan arrays & Nicotra belt-driven fans
  • Ensure default selections are updated to Motor Service Factor 1.1, COPRA EC fans, and Nicotra belt-driven fans where applicable.
πŸ“ New Unit base options for Xtreme Models

  • Painted base, 150 mm base & 200mm base
πŸ“ˆImproved unit Performance

  • Increased HEPA & general filter face area to reduce pressure drop and improve airflow performance, Xtreme unit.
  • Updated cooling & heating coil performance in line with Eurovent requirements.
  • Updated heat wheel and energy-class calculations.
  • Enhanced selection accuracy and performance consistency.
πŸ“Š Better Reports

  • Air velocity now displayed with 3 significant figures
  • Example: 1.89 m/s instead of 1.9 m/s
  • Dynamic report generation date added to all printouts.
  • New Eurovent filter certification warnings for improved compliance awareness.
πŸ› οΈ Key Fixes

  • Xtreme unit base disappearing issue
  • PHE sketch scaling & distortion
  • Xtreme attenuator pressure-drop reset
  • Attenuator sketch & pricing
  • Heater starter costing for larger units
  • Missing 3400 DRI heat-wheel size
πŸ“ž When to Contact the Factory

Please obtain factory confirmation if:
  • Serck coil price is zero, or a costing warning appears.
  • SS Serck coil casing is required but the report shows GI.
  • A double-motor fan application requires confirmation of fan-section length.
  • Customized/non-standard dimension: Cooling coil should be from 3rd party – Contact factory for selections/pricing
πŸ” Selection Check

  • Verify Hygienic AHU settings and unit base when opening online selections in Offline mode. 
  • Maintain fan outlet velocity below 15 m/s for standard applications.
  • Ensure default selections are updated to Motor Service Factor 1.1, COPRA EC fans, and Nicotra belt-driven fans where applicable.
πŸ” Enhanced Software Security

A new 24-hour credential validation has been introduced.

  • Uses the user’s CCSI account credentials.
  • Invalid or deactivated credentials will prevent the unit from being used.
  • Successful validation remains active for the next 24 hours.

⚠️ IMPORTANT β€” ORDER RELEASE REQUIREMENTS

  • Mandatory for all factory orders from 13-Sep-2026. Before quotation and order entry:

  • Refresh Unit Settings and re-run all modules

  • For selections created before v1.07, remove and re-add all coils

  • Review the complete TA selection, report, BOM and costing

  • Use Xtreme Design for all standard orders, Hygienic units still using CLCP -XP Hyg